Banner CMI


English French Nederlands

CMI - DataTrace Temperature Datalogger

 




Temperature


MPRFTemp.jpg, 6,2kB

DataTrace RF Temperature Datalogger


  • Monitor process in real time radio frequency
  • Operating Temperature : - 80°C to + 140°C
  • Accuracy : < 0.1°C between - 40°C to + 140°C and < 0,3°C between - 80°C à - 40°C
  • Operating Pressure : 0 to 10 absolute bars
  • Memory : 8,000 time/temperature
  • Sample rates : 1 sec to 10 min
  • Tightness : IP68
  • Size (body) : D=22 mm x H= 90 mm
  • Probe type : rigid or bendable
  • Material : 316 stainless steel and PTCFE
  • Weight : ≈ 90 g
  • Battery type : lithium ( field-replaceable )
  • Certifications : ATEX Zone 0
  • Delivered with calibration certificate

  • MicropackIII.jpg, 7,8kB

    DataTrace Micropack III Temperature Datalogger


  • Operating Temperature : - 20°C to + 140°C
  • Accuracy : < 0.1°C
  • Operating Pressure : 0 to 10 absolute bars
  • Memory : 16,000 time/temperature
  • Sample rates : 1 sec to 18 hours
  • Tightness : IP68
  • Size (body) : D=18mm x H=21mm
  • Probe type : rigid or flexible with taper or needle tip
  • Material : 316 stainless steel
  • Weight : ≈ 15 g
  • Battery type : lithium ( field-replaceable )
  • Certifications : ATEX Zone 0
  • Delivered with calibration certificate

  • MPIIIHTEXT.jpg, 43kB

    DataTrace Micropack III High Temperature Datalogger


  • Operating Temperature : - 20°C to + 400°C (require a Thermal Pack barriers for use above 140°C)
  • Accuracy : < 0.25°C between - 20 to + 200°C and < 0,5°C between + 200°C et + 400°C
  • Operating Pressure : 0 to 10 absolute bars
  • Memory : 16,000 time/temperature
  • Sample rates : 1 sec to 18 hours
  • Tightness : IP68
  • Size (body) : D=18mm x H=21mm
  • Probe type : flexible with taper or needle tip
  • Material : 316 stainless steel
  • Weight : ≈ 20 g
  • Battery type : lithium ( field-replaceable )
  • Certifications : ATEX Zone 0
  • Delivered with calibration certificate

  • DualProbe.jpg, 33kB

    DataTrace Micropack III Temperature Dual and High Temperature Dual Datalogger


  • Operating Temperature : - 20°C to + 400°C (require a Thermal Pack barriers for use above 140°C)
  • Accuracy :
    Model - 20°C to + 140°C : < 0.1°C
    Model - 20°C to + 400°C : < 0.25°C between - 20 to + 200° and < 0,5°C between + 200°C et + 400°C
  • Operating Pressure : 0 to 10 absolute bars
  • Memory : 16,000 time/temperature
  • Sample rates : 1 sec to 18 hours
  • Tightness : IP68
  • Size (body) : D=18mm x H=28mm
  • Probe type : 2 rigid or flexible probes with taper or needle tip
  • Material : 316 stainless steel
  • Weight : ≈ 20 g
  • Battery type : lithium ( field-replaceable )
  • Certifications : ATEX Zone 0
  • Delivered with calibration certificate

  • ThermalPackFamily.jpg, 5,6kB
    Thermal3000.jpg, 6,1kB
    Thermal3080 .jpg, 6,0kB

    Thermal Barriers


    Thermal Pack 3000
  • Cylinder : D=75mm x L=120mm
  • Performance : 59min at 250°C or 42min at 350°C or 38min at 400°C

  • Thermal Pack 3080
  • Rectangular Box : L=95mm x l=82mm x H=46mm
  • Performance : 36min at 250°C or 27min at 350°C or 24min at 400°C

  • Thermal Pack 3140
  • Cylinder : D=50mm x L=140mm
  • Performance : 109min at 250°C or 77min at 350°C or 68min at 400°C

  • Thermal Pack 3175
  • Cylinder : D=30mm x L=175mm
  • Performance : 93min at 250°C or 61min at 350°C or 53min at 400°C

  • Thermal Pack 3200
  • Cylinder : D=50mm x L=200mm
  • Performance : 195min at 250°C or 135min at 350°C or 120min at 400°C

  • Thermal Pack 3400
  • Cylinder : D=50mm x L=400mm
  • Performance : 380min at 250°C or 240min at 350°C or 205min at 400°C



  • Belgium
    Avenue du Ramelot, 3
    B-1480 Saintes (Sint-Renelde)
    Tel: +32 2 531 11 21
    Fax: +32 2 531 11 29
    E-mail: info@cmitest.com

     

    France
    Siege sociale:
    Ecoparc d'Affaires
    Domaine de Villemorant
    F- 41210 Neung-sur-Beuvron
    Agence Rhone Alpes:
    F- 26450 Cleon d'andran
    Tel: +33 2 54 95 70 95
    Fax: +33 2 54 83 71 90
    E-mail: infofr@cmitest.com

     

    Nederland
    Bredaseweg 185
    NL - 4872 LA Etten-Leur
    Tel: +31 76 530 23 04
    Fax: +31 76 508 35 01
    E-mail: infonl@cmitest.com

     


     