CMI - Humidity and Temperature Calibrator

 




Humidity & Temperature



S904.jpg, 10kB

Relative Humidity Calibrator S904


  • Relative humidity range : 10...90% RH with a 0.2 % HR stability (20…80% RH)
  • Temperature range : + 10°C*...+ 50°C with a ± 0,1°C stability
  • Chamber dimensions : L=105 x h=105 x P=160 mm (V=2 dm3)
  • Control sensor accuracy :
  • Humidity : < 2% RH
  • Temperature : < 0.1°C
  • Humidity generation by mixture of flow dry and saturated air
  • Temperature generation by a four-zone-Peltier heat pump
  • Double skin chamber for a maximum stability and a minimum temperature gradient
  • Stability time between 2 levels : < 10 minutes
  • Humidity and temperature controlled chamber : manual or automatic (PC)
  • Calibrator dimensions : L= 520 x H=290 x P=420 mm
  • Weight : 20 Kg
  • Power supply : 85-264 VAC, 47-63 Hz, 150 VA
  • Delivered with a 5 ports door and a traceable UKAS calibration certificate

  • * Lowest temperature set point = 10°C below ambient

    Optical.jpg, 11kB

    Relative Humidity Calibrator OPTI-CAL with cooled miror integrated


  • Relative humidity range : 10...90% RH with a 0.2 % HR stability (20…80% RH)
  • Temperature range : + 10°C*...+ 50°C with a ± 0,1°C stability
  • Chamber dimensions : L=105 x h=105 x P=160 mm (V=2 dm3)
  • Integral cooled miror reference hygrometer, accuracy :
  • Humidity : < 1% RH between 10 and 70% RH & < 1,5% RH between 70 et 90% RH
  • Temperature : < 0,1°C
  • Humidity and temperature controlled by 2 separate sensors to the reference instrument
  • Humidity generation by mixture of flow dry and saturated air
  • Temperature generation by a four-zone-Peltier heat pump
  • Double skin chamber for a maximum stability and a minimum temperature gradient
  • Stability time between 2 levels : < 10 minutes
  • Humidity and temperature controlled chamber : manual or automatic (PC)
  • Calibrator dimensions : L= 520 x H=290 x P=420 mm
  • Weight : 20 Kg
  • Power supply : 85-264 VAC, 47-63 Hz, 150 VA
  • Delivered with a 5 ports door, the OPTI-SOFT software and an UKAS calibration certificate

  • * Lowest temperature set point = 10°C below ambient



    Belgium
    Avenue du Ramelot, 3
    B-1480 Saintes (Sint-Renelde)
    Tel: +32 2 531 11 21
    Fax: +32 2 531 11 29
    E-mail: info@cmitest.com

     

    France
    Siege sociale:
    Ecoparc d'Affaires
    Domaine de Villemorant
    F- 41210 Neung-sur-Beuvron
    Agence Rhone Alpes:
    F- 26450 Cleon d'andran
    Tel: +33 2 54 95 70 95
    Fax: +33 2 54 83 71 90
    E-mail: infofr@cmitest.com

     

    Nederland
    Bredaseweg 185
    NL - 4872 LA Etten-Leur
    Tel: +31 76 530 23 04
    Fax: +31 76 508 35 01
    E-mail: infonl@cmitest.com

     


     

     

    Designed and Hosted by Business IT Supports